Measurement of Local Ski Boot Deformation in Alpine Skiing Using Printed Sensors in a Laboratory Setting
Jakob Lindlbauer, Hermann Schwameder, Andreas Tschepp, Matthias Hammer, Martin Zirkl, Helmut Holzer, Gerhard Reiter, Christoph Thorwartl (2026): Measurement of Local Ski Boot Deformation in Alpine Skiing Using Printed Sensors in a Laboratory Setting In: Sports Biomechanics (RSPB)
Introduction: In alpine skiing the ski boot acts as the mechanical interface between the athlete and the ski. Local boot deformation indicates how movements and loads are transferred through the leg-boot-ski system. While measuring ski boot deformation has been piloted using inertial measurement units and goniometers (Petrone et al., 2013), a printed-electronics approach, capable of resolving detailed boot deformation characteristics, has not yet been investigated. PyzoFlex® sensor systems have previously been shown to reliably capture dynamic ski deformation under laboratory and field conditions (Thorwartl et al., 2022). Building on this work, this study introduces a PyzoFlex®-based instrumented ski boot prototype employing the crossed sensor layout proposed by Thorwartl et al. (2024). The objectives are (i) the development of a functional PyzoFlex® ski boot prototype and (ii) the execution of controlled laboratory tests to evaluate sensor signal sensitivity and discriminability across different deformation levels and sensor positions.
Methods: A ski boot prototype instrumented with PyzoFlex® sensors was tested using a Flex Checker device. The boot was mounted in a reference position corresponding to 18° forward lean. From this reference position, the ski boot was cyclically deformed forward and backward for 18 loading cycles at four deformation levels (2°, 7°, 12°, 13°). Sensor signals were sampled at 66 Hz and conditioned using an RC feedback branch with R = 1 MΩ and C = 1 nF. Signal droop due to the high-pass behaviour of the piezoelectric circuit was compensated using model-based inverse filtering, with residual drift reduced by assuming identical mechanical states at the start and end of each cycle. Cyclic loading events were identified via adaptive peak detection for segmentation and time-normalization. Peak values were compared across deformation settings and sensor positions using a two-way ANOVA.
Results: Significant effects were observed for Load and Sensor, while the Load × Sensor interaction was not significant. Flex Checker reference data showed significant differences between all deformation settings.
Discussion and conclusion: PyzoFlex® sensors showed clear discrimination between deformation levels and sensor positions, with high repeatability, indicating plausible measurements of local ski boot deformation under laboratory conditions. Positive and negative signal signs reflect compressive and tensile loading, respectively, which in this specific setup are the dominant deformation modes. Adaption of the sensor array processing could enable the additional capturing of the torsional deformation mode, which has already been demonstrated in skis (Thorwartl et al., 2024). A limitation of the current setup is the rectangular geometry of the PyzoFlex® sensor elements, which results in orientation-dependent sensitivity. Future work should therefore consider isotropic circular sensor geometries. Overall, the results demonstrate that ski boot deformation can be measured sensitively using PyzoFlex®, providing a basis for further biomechanical analysis of load transfer within the leg-boot-ski system and boot-fitting applications.